3D/4D Volume Geometry, Spatial Transforms, and NIfTI Export
Source:vignettes/volume-geometry.Rmd
volume-geometry.RmdOverview
Medical cross-sectional imaging (CT, MR, PET, SPECT) inherently captures 3D volumes across space and time. However, different software ecosystems adopt contrasting spatial coordinate systems:
-
DICOM Patient Coordinate System (LPS):
- : towards the patient’s Left
- : towards the patient’s Posterior
- : towards the patient’s Superior (head)
- Defined by
ImageOrientationPatient(, direction cosines) andImagePositionPatient().
-
Neuroimaging / NIfTI Coordinate System (RAS):
- : towards the patient’s Right (inverted from LPS)
- : towards the patient’s Anterior (inverted from LPS)
- : towards the patient’s Superior
- Represented by a
homogeneous affine transformation matrix (
sform) and quaternion rotation (qform).
dicomtk v0.2.0 introduces end-to-end,
standards-compliant 3D/4D volume processing: -
dicom_volume: An S3 class binding numerical voxel arrays
with analytical affine matrices and slice metadata. -
read_dicom_volume(): Geometry-aware reader for multi-slice
directories and enhanced multi-frame DICOM IODs. -
dicom_orientation(), dicom_to_lps(),
dicom_to_ras(): Lossless spatial transformations. -
dicom_pet_suv(), dicom_apply_voi_lut(),
dicom_mr_rescale(): Modality-specific quantitative physics
calibrations. - write_nifti():
dcm2niix-compatible NIfTI-1 export with BIDS JSON
sidecars.
1. Synthesizing Ground-Truth Medical Phantoms
For testing and reproducible research,
dicom_synthesize() generates standards-compliant DICOM
series for CT, MR, and PET modalities with known ground truth geometry,
orientations (axial, coronal, sagittal, or oblique), and optional gantry
tilt.
synth_dir <- tempfile("phantom_ct_")
dir.create(synth_dir, recursive = TRUE)
# Generate a 4-slice oblique CT phantom
phantom <- dicom_synthesize(
out_dir = synth_dir,
modality = "CT",
dims = c(32L, 32L, 4L),
spacing = c(0.8, 0.8, 2.5),
origin = c(-20.0, -15.0, 10.0),
orientation = "oblique",
oblique_angles_deg = c(15, -10, 5),
phi = FALSE
)
# Inspect synthesized files
length(phantom$files)
#> [1] 4The returned generator object contains exact analytical ground-truth
values for truth_affine_lps, truth_voxels,
direction, and spacing.
2. Reading 3D Volumes with read_dicom_volume()
read_dicom_volume() inspects all slices in a folder,
sorts them along the slice-normal trajectory, calculates the analytical
voxel-to-world affine matrix, and verifies slice continuity:
vol <- read_dicom_volume(synth_dir)
# Print summary of S3 dicom_volume object
vol
#> <dicom_volume [CT] 32x32x4 | coord=LPS | units=HU>
#> spacing: (0.8, 0.8, 2.5) mm | origin: (-20, -15, 10) mm
#> frame_meta: 4 row(s) | provenance: 1 step(s)
# Inspect dimensions and affine matrix
dim(vol)
#> [1] 32 32 4
vol$affine
#> [,1] [,2] [,3] [,4]
#> [1,] -0.21796232 0.7610010 -0.3613386 -20
#> [2,] 0.76666649 0.2039096 -0.3223960 -15
#> [3,] 0.06866532 0.1389185 2.4526507 10
#> [4,] 0.00000000 0.0000000 0.0000000 1Checking Orientation
dicom_orientation() extracts the standard 3-letter
patient anatomical direction code (e.g., LPS for axial,
LIP for coronal, PIR for sagittal):
dicom_orientation(vol)
#> [1] "LPS"
sag_dir <- tempfile("phantom_sag_")
dicom_synthesize(out_dir = sag_dir, modality = "MR", dims = c(16L, 16L, 4L), orientation = "sagittal", phi = FALSE)
vol_sag <- read_dicom_volume(sag_dir)
dicom_orientation(vol_sag)
#> [1] "PIR"
unlink(sag_dir, recursive = TRUE)3. Transforming Between LPS and RAS Coordinate Spaces
To interface cleanly between DICOM clinical viewers (LPS) and
neuroimaging packages like FSL, SPM, ANTs, or FreeSurfer (RAS), use
dicom_to_ras() (to_ras()) and
dicom_to_lps() (to_lps()):
# Convert world coordinate frame from DICOM LPS to Neuroimaging RAS
vol_ras <- dicom_to_ras(vol)
vol_ras$coord_system
#> [1] "RAS"
# Anatomical axis directions remain invariant because voxel memory is unpermuted
dicom_orientation(vol_ras)
#> [1] "LPS"
# Inspect the negated X/Y rows of the 4x4 RAS affine
vol_ras$affine
#> [,1] [,2] [,3] [,4]
#> [1,] 0.21796232 -0.7610010 0.3613386 20
#> [2,] -0.76666649 -0.2039096 0.3223960 15
#> [3,] 0.06866532 0.1389185 2.4526507 10
#> [4,] 0.00000000 0.0000000 0.0000000 1to_ras() and to_lps() premultiply
affine and direction by
diag(c(-1, -1, 1, 1)) (a 180-degree rotation around the
Superior
axis,
)
without permuting in-memory voxel arrays, preserving right-handedness
and physical world correspondence.
4. Modality Quantitative Transforms
Raw stored pixel values in DICOM are typically integers requiring physics calibrations before analysis.
PET Standardized Uptake Value (SUV)
PET scanners record radioactivity concentrations (BQML).
dicom_pet_suv() calculates SUV normalized by patient Body
Weight (bw), Lean Body Mass (lbm), or Body
Surface Area (bsa), with radioactive half-life decay
compensation:
pet_dir <- tempfile("phantom_pet_")
dicom_synthesize(out_dir = pet_dir, modality = "PT", dims = c(16L, 16L, 2L), phi = FALSE)
pet_vol <- read_dicom_volume(pet_dir)
# Compute body-weight SUV (g/ml)
pet_suv <- dicom_pet_suv(pet_vol, method = "bw")
pet_suv
#> <dicom_volume [PT] 16x16x2 | coord=LPS | units=g/ml>
#> spacing: (1, 1, 2.5) mm | origin: (-16, -16, 0) mm
#> frame_meta: 2 row(s) | provenance: 2 step(s)
unlink(pet_dir, recursive = TRUE)Mammography & Radiography VOI LUT
For digital radiography (DX) and mammography
(MG), dicom_apply_voi_lut() maps stored pixel
values using standard DICOM PS3.3 LINEAR,
LINEAR_EXACT, or SIGMOID transfer functions
and automatically inverts MONOCHROME1 images:
mg_dir <- tempfile("phantom_mg_")
dicom_synthesize(out_dir = mg_dir, modality = "MG", dims = c(16L, 16L, 1L), phi = FALSE)
mg_vol <- read_dicom_volume(mg_dir)
mg_viewable <- dicom_apply_voi_lut(mg_vol)
range(mg_viewable$voxels)
#> [1] 0.3392436 0.8779687
unlink(mg_dir, recursive = TRUE)Philips MR Private Scaling
Philips MR scanners store console display rescale parameters
(0028,1052) / (0028,1053) alongside private
quantitative scaling intercept (2005,100D)
(ScaleIntercept) and slope (2005,100E)
(ScaleSlope). dicom_mr_rescale() recovers
floating-point physical values
per Chenevert et al. (2014):
mr_dir <- tempfile("phantom_mr_")
dicom_synthesize(
out_dir = mr_dir,
modality = "MR",
dims = c(16L, 16L, 2L),
extra_tags = list(
RescaleIntercept = "0",
RescaleSlope = "2.0",
"(2005,100D)" = "0",
"(2005,100E)" = "4.0"
),
phi = FALSE
)
mr_vol <- read_dicom_volume(mr_dir)
mr_phys <- dicom_mr_rescale(mr_vol, philips_float = TRUE)
mr_phys
#> <dicom_volume [MR] 16x16x2 | coord=LPS>
#> spacing: (1, 1, 2.5) mm | origin: (-16, -16, 0) mm
#> frame_meta: 2 row(s) | provenance: 2 step(s)
unlink(mr_dir, recursive = TRUE)5. Exporting to NIfTI-1 with BIDS Sidecar
(write_nifti())
write_nifti() writes standards-compliant NIfTI-1
(.nii) files matching Chris Rorden’s dcm2niix
specification:
- Exact
sformaffine matrix in RAS coordinate space. - Exact
qformquaternion rotation derived via polar SVD decomposition. - Companion BIDS JSON sidecar (
<filename>.json) capturing scanner parameters (RepetitionTime,EchoTime,SliceThickness,SpacingBetweenSlices).
out_nii <- tempfile(fileext = ".nii")
bids_json <- sub("\\.nii$", ".json", out_nii)
write_nifti(vol, out_nii, json_sidecar = TRUE)
file.exists(out_nii)
#> [1] TRUE
file.exists(bids_json)
#> [1] TRUE
# Clean up
unlink(c(synth_dir, out_nii, bids_json), recursive = TRUE)6. Full Backward Compatibility
All existing functions from dicomtk v0.1.0 remain fully
functional: - read_dicom_series() delegates directly to
read_dicom_volume(). - dicom_to_nifti()
delegates directly to write_nifti().