Segmentation, Radiotherapy (RTSTRUCT/RTDOSE), and Deep Learning Prep
Source:vignettes/segmentation_and_rt.Rmd
segmentation_and_rt.RmdOverview
dicomtk 0.4.0 introduces end-to-end support for
DICOM Segmentation (SEG),
Radiotherapy (RTSTRUCT and
RTDOSE), Quantitative Structured Reports
(TID 1500), Grayscale Presentation States
(GSPS), Automated Image Quality
Control, and ML Dataset Exporters
(nnU-Net v2, MONAI, RO-Crate,
Croissant).
1. Creating and Writing a DICOM Segmentation
(dicom_seg)
Because dicom_seg inherits from
dicom_volume, it preserves full 3D LPS/RAS spatial geometry
alongside segment metadata:
library(dicomtk)
synth <- dicom_synthesize(modality = "CT", dims = c(32L, 32L, 6L))
vol <- read_dicom_volume(synth[["out_dir"]])
mask <- array(0L, dim = dim(vol))
mask[10:22, 10:22, 2:5] <- 1L
seg <- dicom_seg(
mask = mask,
ref_volume = vol,
segments = tibble::tibble(segment_id = 1L, label = "Liver")
)
seg
#> ℹ DICOM Segmentation Object (Segment rows: 1, Mask dims: 32x32x6)2. Automated Image Quality Control
(dicom_image_qc)
Before feeding volumes into a downstream pipeline or ML trainer, run
dicom_image_qc() to check SNR, CNR, FOV border truncation,
slice spacing anomalies, gantry tilt, and high-frequency ringing:
qc <- dicom_image_qc(vol)
qc$qc_status
#> [1] "PASS"3. Deep Learning Preprocessing (volume_resample,
volume_window)
Resample volumes to isotropic voxel spacing and apply clinical HU windowing:
vol_iso <- volume_resample(vol, target_spacing = c(2, 2, 2), method = "trilinear")
vol_win <- volume_window(vol_iso, center = 40, width = 400, normalize = "minmax")
range(vol_win$voxels)
#> [1] 0 1